2026-11-04 · 5 min read

The number on a stick electrode is the diameter of the steel core, in millimetres. It says nothing about the coating and nothing about the strength of the deposit — those are carried by the rest of the designation. What the diameter does decide is how much current the rod will take, how wide the bead is, and which welding positions it will hold.

Buyers ask which size to order as though it were a matter of preference. It is not. On a 2 mm sheet, a 4 mm electrode at any workable current will burn through before the puddle forms. On 25 mm plate, a 2.5 mm electrode will weld, but the joint takes several times the passes and the operator spends the afternoon making them.

What each size is for

DiameterWhere it belongsPositionsWhere it stops working
2.0 mmThin sheet, tacking, tight root gapsAllFilling anything thick — the pass count becomes the cost
2.5 mmLight fabrication, sheet to a few millimetres, repair workAllHeavy sections; runs out of deposition before it runs out of joint
3.2 mmThe general-purpose size. Most fabrication that is not specifiedAllVery thin sheet, where even low current burns through
4.0 mmMedium plate, structural fillets, fillingFlat, horizontal, vertical-upThin sheet, and open root passes
5.0 mmHeavy plate, long flat runs, high depositionFlat and horizontal onlyAnything out of position — the puddle is too large to control

The line that matters is the last column. Going up a size buys deposition rate and costs position. That is not a rule of thumb about skill; it is a consequence of puddle size. A 5.0 mm electrode at working current makes a puddle that gravity wins against, whatever the operator does.

Why there is no amperage column here

Most diameter charts on the internet print an amperage range beside each size. We are not going to, because the range is not a property of the diameter. Two 3.2 mm electrodes with different coatings run at different currents, and the same electrode runs at a different current depending on whether the joint is a root pass or a fill. A number printed here would be wrong for somebody.

Each grade we supply has a datasheet, and the current range for each diameter it is made in is on that sheet. Ask for it with the quotation and you get the range for the electrode you are actually buying, not for the diameter in the abstract.

The three symptoms worth knowing

  • Current too high: undercut along the toes, spatter, a bead that is wider and flatter than it should be, and a coating that burns back faster than the core melts.
  • Current too low: the arc wanders, the bead sits high and crowned, and the toes do not wet into the plate. The weld looks complete and has no fusion at the edges.
  • Diameter too large for the joint: the arc cannot reach the root, so the first pass is a bridge rather than a penetration. Going up a size does not fix a gap; it hides it.

What we stock

E6013 — the general-purpose rutile electrode — is stocked in 2.0 mm, 2.5 mm, 3.2 mm, 4.0 mm and 5.0 mm, which covers the full ladder above. E6011 and E7018 are quoted per order in the sizes the job needs. E4313 carries the same sizes as E6013 under the GB designation.

If you are choosing between the sizes for a specific joint and want a second opinion, send the plate thickness, the position and the joint preparation. We will tell you which diameter and which grade we would run, and why.